EMI
Electromagnetic Interference
Electromagnetic Interference (EMI) is an unwanted electromagnetic disturbance generated by electrical equipment that can disrupt the performance of railway signalling, telecommunications, train control and other electronic system
Detailed explanation
Electromagnetic Interference (EMI) is a disturbance caused by electromagnetic energy that can affect the normal operation, performance or reliability of electrical and electronic equipment.
In modern railway and metro systems, EMI is a critical engineering consideration because high-power electrical equipment operates close to sensitive signalling, telecommunications, train control and safety-related systems.
1. Sources of EMI in Railway Systems
Electromagnetic interference can originate from several railway subsystems:
Traction Power Systems: High-voltage power supplies, traction substations, transformers and switching equipment.
Overhead Contact Systems (OCS): Pantograph–catenary interactions, electrical arcing and switching transients.
Rolling Stock: Traction motors, inverters, converters, auxiliary power supplies and onboard electronic equipment.
Traction Return Circuits: Return currents flowing through running rails, bonding connections and associated conductive paths.
Electrical Installations: Variable frequency drives (VFDs), generators, UPS systems and other power electronic equipment.
2. Types of Electromagnetic Interference
EMI is generally classified into two main categories:
Conducted EMI: Electromagnetic disturbances transmitted through electrical cables, power supplies, earthing networks or other conductive paths.
Radiated EMI: Electromagnetic disturbances transmitted through electromagnetic fields, potentially affecting nearby electronic equipment without direct electrical connections.
EMI may also occur as continuous disturbances or short-duration transients associated with switching operations, electrical faults and arcing.
3. Impact of EMI on Railway Operations
Uncontrolled EMI can potentially affect:
Signalling Systems: Interference with track circuits, axle counters and train detection equipment.
Train Control Systems: Disturbances affecting electronic equipment associated with ETCS, CBTC and other train control technologies.
Telecommunications: Degradation of GSM-R, FRMCS, radio and wireless communication performance.
SCADA and Control Systems: Communication errors, unreliable measurements and equipment malfunctions.
Passenger Information Systems: Disturbances affecting electronic displays, communication equipment and associated control systems.
In safety-critical railway applications, electromagnetic compatibility must be demonstrated to ensure that interference does not compromise required system performance or safety functions.
4. EMI Mitigation Measures
Railway designers adopt several engineering measures to minimise electromagnetic interference:
Segregation of traction power, signalling and telecommunications cables.
Appropriate cable shielding and screening arrangements.
Effective earthing and equipotential bonding.
EMC filters and surge protection devices.
Proper management of traction return currents.
Selection of equipment complying with applicable EMC standards.
EMC assessments, simulations and testing at equipment and system levels.
5. EMI and Electromagnetic Compatibility (EMC)
EMI and EMC are closely related but have different meanings.
EMI describes the unwanted electromagnetic disturbance that may affect equipment.
EMC describes the ability of equipment and systems to function correctly within their electromagnetic environment without producing unacceptable interference to other equipment.
Railway EMC engineering therefore involves controlling electromagnetic emissions and ensuring that equipment has adequate immunity to disturbances.
Railway applications
mainline, high_speed, metro, light_rail, freight, depot
Standards and references
EN 50121 Series: Railway applications – Electromagnetic compatibility.
IEC 62236 Series: Railway applications – Electromagnetic compatibility.
IEC 61000 Series: Electromagnetic compatibility testing and assessment.
EN 50122-1: Railway electrical safety, earthing and return circuits.
EN 50238 Series: Compatibility between rolling stock and train detection systems.